In-house cleanliness verification using particle count, NVR gravimetric testing, UV inspection, and visual examination, so your parts ship with documentation your customer can accept, without waiting on a third-party lab.
IEST-STD-CC1246E (Institute of Environmental Sciences and Technology) is the industry benchmark for defining and verifying the cleanliness of surfaces, components, and assemblies. It establishes quantitative levels for both particulate contamination and non-volatile residue (NVR).
At Jetsons, we use this standard as our guiding framework for cleanliness inspection. We perform hands-on extraction, particle count evaluation, gravimetric analysis, and visual inspection to confirm your components comply with whatever IEST-1246E cleanliness level your specification demands.
Whether your requirement comes from a defense contract, aerospace OEM, medical device manufacturer, or semiconductor process spec, we translate your cleanliness requirement into a structured inspection workflow.
Multiple complementary inspection techniques provide thorough cleanliness confirmation. Each method targets a specific class of contamination.
Extraction fluid flushed across the component surface and passed through a calibrated optical particle counter. Counts by size range compared to IEST-1246E level specified for your part across size bins from 5 to 1250 microns.
IEST-1246E ParticulateSolvent-extracted rinse fluid evaporated and residual mass weighed on a precision analytical microbalance. NVR results (oils, greases, organic films) reported against IEST-1246E R-level limits for your cleanliness requirement.
IEST-1246E NVRExtraction rinse passed through a precision membrane filter. Captured solid mass weighed gravimetrically, providing a total particle burden result that complements optical particle count and confirms overall mass-based cleanliness.
Mass / GravimetricUltraviolet light inspection reveals organic residues, oils, and fingerprint contamination fluorescing on critical surfaces without fluid contact. Ideal where wet extraction is not permitted, or as a supplemental visual check post-cleaning.
Non-ContactDigital dewpoint meter confirms no residual moisture remains after cleaning and drying. Critical for oxygen-service, aerospace, and medical components where trapped moisture causes corrosion or process contamination.
Dryness VerificationConfirmation that no cleaning solvent or agent remains on or within the part after processing. Verified through photoionization detection or rinse conductivity checks to ensure the cleaning medium has not become the contaminant.
Residue VerificationUse these tables to identify the applicable cleanliness level for your component and to understand what our inspection verifies against.
Maximum allowable particle counts per 0.1 m² of surface area per IEST-STD-CC1246E. Cells showing “—” are not applicable for that level.
| Min (μm) | Max (μm) | Lvl 25 | Lvl 50 | Lvl 100 | Lvl 200 | Lvl 300 | Lvl 400 | Lvl 500 | Lvl 750 | Lvl 1000 |
|---|---|---|---|---|---|---|---|---|---|---|
| 5 | 15 | 19 | 141 | 1,519 | n/a | n/a | n/a | n/a | n/a | n/a |
| 15 | 25 | 2 | 17 | 186 | 2,949 | n/a | n/a | n/a | n/a | n/a |
| 25 | 50 | 1 | 6 | 67 | 1,069 | 6,433 | n/a | n/a | n/a | n/a |
| 50 | 100 | 0 | 1 | 9 | 154 | 926 | 3,583 | 10,716 | n/a | n/a |
| 100 | 250 | 0 | 0 | 1 | 15 | 92 | 359 | 1,073 | 8,704 | n/a |
| 250 | 500 | 0 | 0 | 0 | 0 | 2 | 8 | 25 | 205 | 983 |
| 500 | 750 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 7 | 33 |
| 750 | 1000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 3 |
| 1000 | 1250 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 |
Maximum allowable NVR per 0.1 m² of surface area or per 0.1 L of fluid per IEST-STD-CC1246E.
We confirm the target IEST-1246E particulate level and NVR level from your drawing, purchase order, or inspection plan.
Parts received and handled in our controlled environment. Extraction flush performed per the applicable method to collect the inspection sample.
Samples analyzed for particle count by size range, NVR mass, TFS, moisture, and UV fluorescence depending on your requirements.
Results compared to IEST-1246E acceptance limits. Written inspection record with pass/fail determination provided for your quality records.
Tell us your cleanliness level requirement and we will walk you through what inspection methods apply. Fast turnaround, clear documentation, straightforward pricing.